hitachi — Voltage and Current Measurement

TROUBLESHOOTING / Electrical System Inspection VOLTAGE AND CURRENT MEASURE- MENT Turn key switch ON so that the specified voltage (cur- rent) is supplied to the location to be measured. Judge if the circuit is normal by evaluating whether the measured voltage (current) matches the specification. 24-Volt Circuit Start checking the circuit in order up to the loca- tion to be measured from either power source or actuator side. Thereby, the faulty location in the circuit will be found. Black Probe (Negative) of Tester: To ground to the vehicle frame Red Probe (Positive) of Tester: To touch the location to be measured NOTE: *Before measurement, disconnect the negative cable from the battery.

T5-7-10 Engine Key Switch Location to be Measured Specification Power Source Circuit Stopped Stopped Stopped Stopped Stopped Stopped OFF OFF OFF OFF OFF OFF Between (2) and (1): One Battery Between (3) and (2): One Battery Between (3) and (1): Two Batteries Between (4) and Ground: Battery Power Between (5) and Ground: Fusible Link Between (1) and Ground: Backup Current* 10 to 12.5 V 10 to 12.5 V 20 to 25 V 20 to 25 V 20 to 25 V 6 mA Preheat Circuit Stopped Stopped ON or START ON or START Between (6) and Ground: Key Switch Between (7) and Ground: Glow Plug 20 to 25 V 20 to 25 V Charging Circuit Fast Speed Fast Speed Fast Speed Fast Speed Fast Speed ON ON ON ON ON Between (8) and Ground:

Alternator (B) / Generating Voltage Between (9) and Ground: Battery Relay / Generating Voltage Between (10) and Ground: Fuse Box / Starter Relay 2 (R) / Generating Voltage Between (11) and Ground: Generating Voltage Between (12) and Ground: Monitor Unit (C7) 26 to 30 V 26 to 30 V 26 to 30 V 13 to 30 V 13 to 30 V Surge Voltage Prevention Circuit Idle Speed Idle Speed Idle Speed Idle Speed ON ON ON ON Between (8) and Ground: Alternator (B) Between (11) and Ground: Starter Relay 2 (R) Between (13) and Ground: Load Damp Relay Between (9) and Ground: Battery Relay 26 to 30 V 13 to 30 V 26 to 30 V 26 to 30 V Accessory Circuit Stopped Stopped Stopped Stopped ON ON ON ON Between (14) and Ground:

Auxiliary Between (15) and Ground: Cigarette Lighter Between (16) and Ground: Radio, Cab Light Between (17) and Ground: Battery Relay 20 to 25 V 20 to 25 V 20 to 25 V 20 to 25 V