TROUBLESHOOTING / Electrical System Inspection Multi-line continuity check Disconnect both end connectors of the harness, and short-circuit two terminals, (A) and (B), at one end connector, as illustrated. Then, check continuity between terminals (a) and (b) at the other connector. If the ohm-meter reading is Ω , either line (A) - (a), or (B) - (b) is in discontinuity. To find out which line is discontinued, conduct the single line continuity check on both lines individually, or, after changing the short-circuit terminals from (A) - (B) to (A) - (C), check continuity once more between terminals (a) and (c). First short-circuit A B C a b c Second short-circuit Ω NOTE:

By conducting the multi-line continuity check twice, it is possible to find out which line is discontinued. With terminals (A) and (C) short-circuited, check continuity between terminals (a) and (c). If the ohm-meter reading is: 0 Ω = Line (B) - (b) has discontinuity. Ω = Line (A) - (a) has discontinuity. Multi-line short-circuit check Disconnect both end connectors of the harness, and check continuity between terminals (A) and (B) or (C). If the ohm-meter reading is: 0 Ω = Short-circuit exists between the lines. Ω = No short-circuit exists between the lines. T107-07-05-004 Short-circuit between harnesses. Ч A B C a b c Ω T107-07-05-005 T5-7-9