hitachi — Check by False Signal

TROUBLESHOOTING / Electrical System Inspection CHECK BY FALSE SIGNAL Turn the key switch OFF. Disconnect the sensor con- nector. Turn the key switch ON. Connect terminal #1 (power source) of machine harness end connector to terminal #2 (signal). (Power voltage is used as a false signal.) Check this state by using the monitor function of Dr. ZX. When the maximum value is displayed, MC and the circuit up to the machine harness end con- nector are normal. If “ON” is displayed, the pressure switch circuits are normal. IMPORTANT: Do not connect terminal #1 or #2 to terminal #3 or to the vehicle frame (ground) when checking a three-polarity connector.

Two Polarities (Hydraulic Oil Tem- perature Sensor) 2 1 Connect Three Polarities T107-07-05-010 (Pressure Sensor) (Pump Delivery Pressure Sensor) (Pump Control Pressure Sensor) NOTE: Some kinds of sensors can be monitored by the service menu of monitor unit. (Refer to the TROUBLESHOOTING / Monitor Unit group.) 1 3 2 Connect T107-07-05-011 T5-7-17