13 Remove carbon from the injection orifice of the nozzle 12 using the Needle Cleaner of the Cleaning Tool Set. Insert the Needle Cleaner and rotate it to dislodge the carbon. 01893 Clean the seat of the nozzle 12 using the Cleaning Scraper of the Cleaning Tool Set. To remove burned and hardened carbon, use FUSO Carbon Remover. 01894 [Inspection] Wash the needle valve 13 and nozzle 12 in gas oil, then fit them together. Pull up the needle valve 13 by approximately 1/3 of its entire stroke, then check that it drops under its own weight. Repeat this test several times, turning the needle valve each time.
If the needle valve 13 does not drop as required, wash it in gas oil and carry out this test again. If the needle valve is still defective, replace the needle valve and nozzle 12 as a set. 01911 NOTE Whenever a nozzle 12 is replaced, the nozzle and needle valve 13 must be replaced as a set using Nozzle Service Kit. (This applies to Zexel products only.) 13-31