Caterpillar — Caterpillar 99709-68120 — user manual

THERMOSTAT 14-18 G Disassembly sequence 1 Water temperature sensor 2 Thermostat cover 3 Gasket 4 Thermostat 5 Bolt 6 Thermostat case 7 Gasket 8 Front hanger 9 Bypass hose : Non-reusable part NOTE Do not remove thermostat case 6 and front hanger 8 unless they are leaking water or otherwise defective. 16944 G Assembly sequence Reverse the order of disassembly.

Service standards Location Maintenance item Standard value Limit Remedy 1 Water temperature sensor resistance (Between terminal ➀ and body) 50°C (122°F) (136 V)* – Replace 80°C (176°F) 48 ± 5 V – 100°C (212°F) 27.2 ± 2 V – 4 Thermostat Valve opening temperature 76.5 ± 2°C (170 ± 36°F) – Replace Valve lift/temperature 10 mm (0.394 in.) or more at 90°C (194°F) – *: Figures in parenthesis are approximate.