14 Tightening torques Unit: N·m (kgf·m) [lbf·ft] 14-19 Location Parts to be tightened Tightening torque Remarks 1 Water temperature sensor 34 ± 6.9 (3.5 ± 0.7) [25.1 ± 5.1] – Lubricants and sealant Location Points of application Kinds Quantity 5 Threads of bolts (thermostat case mounting) THREEBOND 2302 As required N Service procedure 1 Water temperature sensor inspection • Place water temperature sensor 1 in a container of engine oil. • Heat the oil until it reaches the specified temperatures. Stir the oil to ensure that it heats up evenly. • Measure the resistance between terminal ➀ and body ➁ of the water temperature sensor.
• If the measurements do not conform with the specified values, replace the water temperature sensor 1. 03868 4 Thermostat inspection Place the thermostat in a container of water. While stirring the water with a rod A to ensure that it is heated evenly, carry out the following inspection procedure. If the measurements do not conform with the standard values, replace the thermostat 4. (1) Valve opening temperature • Support thermostat 4 with wire E to keep it away from heat source D. 00218 • Gradually heat the water until it reaches the valve opening temperature. • Maintain this temperature for 5 minutes and check that valve B is open.
• When the water temperature drops below 65°C (149°F), check that valve B is completely closed. C: Thermometer (2) Valve lift Heat the water to slightly higher than the valve opening temperature. With valve B fully open, maintain this water temperature for 5 minutes. Measure the extent of valve lift F.