Caterpillar — Caterpillar 99709-68120 — user manual

54 Field coil [Removal] Remove the two screws A . 15 CAUTION If the screws B are removed first, the weight of the field coil 15 will act on the lead portion secured by the screws A, and damage to the lead portion may result. Therefore, make sure that the screws A are removed first. 16118 Remove the three screws B . CAUTION When the screws B are removed, the field coil 15 will fall under its own weight. Therefore, hold the field coil by hand beforehand. Remove the field coil 15 . CAUTION When the field coil 15 is taken out, the coil lead portion may be caught by the stator coil. Don't pull it out with undue force.

[Inspection] Measure the resistance between the terminals of the field coil 15 . If the reading is out of the standard value, replace the field coil 15 . 02325 17 Inspection of rectifier Check the rectifier 17 to see if the internal diodes function properly, and replace if defective. Resistance infinite in both cases....Open Resistance close to V in both cases...Short A, B, C: Leads of stator coil connected D, F: Heat sink portion E: Regulator connected 13084 Exchange the and sides of the tester and perform checks in both cases.

CAUTION When a tester is used for the checks, the current that flows out from the tester is feebler than the current that normally flows through the rectifier 17, so the tester may indicate a questionable resistance value. In a low range, this tendency will be stronger. Therefore, it is advisable to use the highest possible range. 13083 54-21