Caterpillar — Caterpillar 99709-68120 — user manual

STARTER Magnet switch [Installation] Install the magnet switch 5 on the lever 27 with terminal S in the direction shown. 5 10771 [Inspection] (1) Open circuit test on coil Check to ensure that there is continuity between terminals S and M . If there is no continuity, replace the magnet switch 5 . 10773 Check to ensure that there is continuity between terminal M and body A . If there is no continuity, replace the magnet switch 5 . 10774 (2) Contact fusion check Check to ensure that there is no continuity between terminals B and M . If there is continuity, replace the magnet switch 5 . 10775 (3) Contact contacting check Push the end of the magnet switch 5 in to close the internal contact.

In this state, check to ensure that there is continuity between terminals B and M . If there is no continuity, replace the magnet switch 5 . 10776 54-38