STARTER Inspection of brush (1) Length of brush If the reading is less than the limit, replace the brushes 14 and 15 . 15 14 CAUTION To replace the brush 14, replace the brush holder assembly 16. 02465 (2) Commutator contacting surfaces If the contacting surfaces are rough or unevenly worn, repair with emery paper (#300 to 500). 16 Inspection of brush holder assembly Check to ensure that there is no continuity between the side brush holder and side holder plate. If there is continuity, it means a short circuit. Replace the brush holder assembly 16 . 02467 Inspection of yoke assembly (1) Open circuit test on coil Check to ensure that there is continuity between cable A and brush 15 .
If there is no continuity, it means an open circuit. Replace the brush 15 or yoke assembly 17 . 17 02477 (2) Ground test on coil Check to ensure that there is no continuity between the yoke assembly 17 and brush 15 . If there is continuity, it means a short circuit. Check the insulation. If repair is impossible, replace the brush 15 or yoke assembly 17 . 02478 Inspection of armature assembly (1) Short circuit test on coil Bring the iron piece A close to the armature assembly 18 , keeping it in parallel. Slowly rotate the armature assembly 18 by hand. If the iron piece A is attracted or vibrates, it means a short circuit. Replace the armature assembly 18 . 18 02471 54-40