ON-VEHICLE INSPECTION AND ADJUSTMENT 11-10 Inspecting and Adjusting Valve Clearances Service standards Unit: mm (in.) Location Maintenance item Standard value Limit Remedy – Valve clearance (when cold) 0.4 (0.0158) – Adjust Tightening torques Unit: N·m (kgf·m) [lbf·ft] Location Parts to be tightened Tightening torque Remarks 2, 3 Rocker arm adjusting screw lock nut 34 (3.5) [25.1] – Valve clearances should be checked and adjusted when the engine is cold. [Inspection] • Bring piston No. 1 or piston No. 6 to the top-dead-centre (TDC) position of its compression stroke.
To do this, crank the engine until the “1.6” mark inscribed on the flywheel is aligned with the pointer A in the flywheel housing inspection window. NOTE Pistons whose push rods are not pushing up their rockers are at top-dead-centre (TDC) of their compression strokes. 01940 • When piston No. 1 or piston No. 6 is at the TDC position of its compression stroke, measure the clearance B of every valve marked “ ” in the following table. Piston No. 1 2 3 4 5 6 Valve arrangement In. Ex. In. Ex. In. Ex. In. Ex. In. Ex. In. Ex. No. 1 piston at TDC of compression stroke 11620 No. 6 piston at TDC of compression stroke NOTE To measure the clearance, insert a feeler gauge 1.
The gauge should be able to move in the gap, albeit not loosely. Accurate measurements cannot be taken if the gauge moves loosely in the gap. Piston No. 1 2 3 4 5 6 Valve arrangement In. Ex. In. Ex. In. Ex. In. Ex. In. Ex. In. Ex. No. 1 piston at TDC of compression stroke No. 6 piston at TDC of compression stroke