8 4 Brakes – 4.3.1 Brake oil pump 4.3.1 Brake oil pump page Brake oil pump, checking WARNING Hot, pressurized oil. Personal injury, burn injury, rash or irritation. Always depressurize the hydraulic systems before starting to work in the hydraulic systems. Avoid skin contact with the oil, use protective gloves. 1 Operate and warm up the machine so that the oil in the brake system reaches operating temperature, at least 50 ° C. 2 Machine in service position, see section B Safety 3 Depressurize the brake and hydraulic systems, see section B Safety . 4 Connect a pressure gauge (0–25 MPa) to the test outlet for pump pressure on the accumulator charging valve. 5 Start the engine and let it idle.
6 Close the drain valve on the accumulator charging valve and check the pump pressure during charging. During charging, the pressure should increase to 19 ± 0.5 MPa before the accumulator charging valve switches to cooling. When the accumulator charging valve shifts to cooling, the pressure drops. 7 Check the pressure during cooling. During cooling the pressure should be max. 1–1.5 MPa at max. engine rpm. 8 Turn off the engine. 9 Depressurize the brake and hydraulic systems, see section B Safety , Hydraulic and brake systems, depressurizing . 10 Remove the pressure gauge and fit the protective cap on the pressure check connection. 11 Close the drain valve on the accumulator charging valve.
UDRF01.04GB Maintenance manual DRF 400–450