4 Brakes – 4.3.4 Accumulator 9 4.3.4 Accumulator page Accumulator, checking 1 Start the engine and let it idle for approx. 1 minute (until the ac- cumulator charging valve switches to cooling). 2 Turn off the engine and turn the start key to position I. 3 Apply and release the brake several times, and count the number of times that the brake can be applied before the warn- ing light for low brake pressure is activated. It should be possible to apply the brake 8 times before the warning light for low brake pressure is activated. If the warning light for low brake pressure is activated, one of the brake system's accumulators is probably defective and these should therefore be checked further.
UDRF01.04GB Maintenance manual DRF 400–450