7 Load handling – 7.9.1.7 Twistlocks 45 page Twistlock, checking for cracks DANGER Material fatigue, reduced strength. Fatal danger! Change twistlocks that shows signs of cracks or other external damage, or twistlocks with more than 10 000 operating hours. NOTE Crack checks shall take place every other year or every 5000 operating hours. 1 Remove the lift pins from the attachment. NOTE Twistlocks are heavy. Take care when removing. 2 Test for cracks within the marked area on the pins without re- working or damaging the part. 3 If the lift pins show signs of cracking, they shall be replaced with new ones. 4 Fit approved twistlocks. Area for checking for cracks on lift shoe.
NOTE Use new attaching nut and washers. UDRF01.04GB Maintenance manual DRF 400–450 002313