7 Load handling – 7.10.2 Weight indicator 59 page Weight indicator, checking (product alternative fixed scale) 1 Lift a known weight. 2 Place the boom in horizontal position. A. Lift the boom so that the colour marking on the rod disap- pears in the pipe. Event menu dynamic scale B. Lower the boom until the colour marking can be seen. C. Press in the pistol trigger and extend the boom. The display now shows the scale symbol and a flashing weight value. When the boom is in the right position(approx. 0.5 m out) the boom stops by itself, the weight value stops flashing and the digits become larger. 3 Check that the weight indicator shows the correct weight ± 0.5 ton.
If the deviation is greater, calibrate the weight indicator. page Fixed scale, calibration NOTE It is very important for accuracy that all steps are performed in the specified order. 1 Park the machine on level ground without load and centre the attachment. 2 Navigate to the service menu and press ENTER. 3 Enter code for calibration. Code is obtained from Kalmar Industries Support. NOTE The code determines which service menu is activated (Di- agnostic test, Initiation or Calibration). 4 Scroll to SCALE with the arrow keys (1 and 2) and press ENTER. Every calibration consists of a sequence of a number of menus. The first menu for selected calibration appears in the display.
Select the next menu with the arrow keys (1 and 2). UDRF01.04GB Maintenance manual DRF 400–450 000575 000056 1 2 3 4 5 000060 1 2 3 CALIBRATION 000062 SCALE STEERING DRIVE-TRAIN RETURN