Kaiyi UDRF01.04GB — 7.10.2 Weight indicator

60 7 Load handling – 7.10.2 Weight indicator 5 Move the boom to measuring position. A. Lift the boom so that the colour marking on the rod (pos A) disappears in the pipe. B. Lower the boom until the colour marking can be seen at the pipe end (pos B). C. Press in the pistol trigger (Pos C) and extend the boom. The display now shows the scale symbol and a flashing weight value. A When the boom is in the right position(approx. 0.5 m out) the boom stops by itself, the weight value stops flashing and the digits become larger. B C 001132 6 CALIBR SCALE, menu 1, save the setting with ENTER. 7 Lift a known reference load and centre the attachment. 8 Park the machine on level ground.

9 Move the boom to measuring position, see step 5. NOTE It is very important for accuracy that the boom is raised first and then lowered to the measuring position. 10 Scroll to CALIBR SCALE, menu 2. 11 Enter the weight of the reference load with the + and - keys. Save the setting with ENTER. The weight is given in tons, to one decimal. 12 Scroll back from the calibration mode with the R-key. 13 Check the calibration, see Weight indicator, checking (product alternative fixed scale) page 59 . UDRF01.04GB Maintenance manual DRF 400–450 CA BO WI LE 000071 LIBR SCALE 1(3) OM IN MEASURE POS THOUT LOAD X.XXV RI X.XXV CA BO WI LE 000072 LIBR SCALE 2(3) OM IN MEASURE POS TH LOAD XX.XT X.XXV RI X.XXV