Kaiyi UDRF01.04GB — 7.10.2 Weight indicator

62 7 Load handling – 7.10.2 Weight indicator page Weight indicator, checking (product alternative dynamic scale) 1 Lift a known weight. 2 Check that the weight indicator shows the correct weight ± 0.5 ton. If the deviation is greater, calibrate the weight indicator. Operating menu dynamic scale a. Measured weight of load b. load-centre measured from drive axle's centre c. use of load capacity at load-centre in question page Dynamic scale, calibration NOTE It is very important for accuracy that all steps are performed in the specified order. 1 Park the machine on level ground without load and centre the attachment. 2 Navigate to the service menu and press ENTER. 3 Enter code for calibration.

Code is obtained from Kalmar Industries Support. NOTE The code determines which service menu is activated (Di- agnostic test, Initiation or Calibration). 4 Scroll to SCALE with the arrow keys (1 and 2) and press ENTER. Every calibration consists of a sequence of menus. Scroll be- tween menus with the arrow keys. 5 Lower the boom to the lowest position (0 ° ). 6 CALIBR SCALE, menu 1 and save the setting with ENTER. 7 Lift the boom to its highest angle. UDRF01.04GB Maintenance manual DRF 400–450 a b c 000357 000056 1 2 3 4 5 000060 1 2 3 CALIBRATION 000062 SCALE STEERING DRIVE-TRAIN RETURN 000064 CALIBR SCALE 1(7) MINIMUM BOOM ANGLE CALIBR VALUE X.XXV PRESENT VALUE X.XXV