Kaiyi UDRF01.04GB — 7.10.2 Weight indicator

7 Load handling – 7.10.2 Weight indicator 63 8 Scroll to CALIBR SCALE, menu 2 and save the setting with EN- TER. 9 Retract the boom completely. 10 Scroll to CALIBR SCALE, menu 3 and save the setting with EN- TER. 11 Extend the boom completely. 12 Scroll to CALIBR SCALE, menu 4 and save setting with ENTER. 13 Lower and retract the boom completely. 14 Raise the boom approx. 4 cm (on the lift cylinders). 15 Lower the boom carefully approx. 2 cm (on the lift cylinders). 16 Wait approx. five seconds to stabilize the pressure. 17 Scroll to CALIBR SCALE, menu 5 and save the setting with EN- TER. NOTE Negative values indicate changed contacts on the pres- sure sensors.

Large variations between right and left indicate faults in the sensors' signals. 18 Extend the boom completely. 19 Wait approx. five seconds to stabilize the pressure. 20 Scroll to CALIBR SCALE, menu 6 and save the setting with EN- TER. Checking calibration 21 Scroll to CALIBR SCALE, menu 7. 22 Lift a reference weight and check that the control system cal- culates the correct weight of the load the machine is lifting, PRESENT LOAD. 23 If the weight is not quite correct, scroll to menu 6 and enter the weight of the reference load with the + and - keys. Save the set- ting with ENTER. The weight is given in whole tons.

UDRF01.04GB Maintenance manual DRF 400–450 000065 CALIBR SCALE 2(7) MAXIMUM BOOM ANGLE CALIBR VALUE X.XXV PRESENT VALUE X.XXV 000066 CALIBR SCALE 3(7) BOOM FULLY RETRACTED CALIBR VALUE X.XXV PRESENT VALUE X.XXV 000067 CALIBR SCALE 4(7) BOOM FULLY EXTENDED CALIBR VALUE X.XXV PRESENT VALUE X.XXV 000068 CALIBR SCALE 5(7) LOAD SENSOR BOOM RETRACTED LE RI CALIBR XXXX XXXX PRESENT XXXX XXXX 005119 CALIBR SCALE 6(7) LOAD SENSOR BOOM XX EXTENDED LE RI CALIBR XXXX XXXX PRESENT XXXX XXXX 000070 CALIBR SCALE 7(7) ALLOWED LOAD XXXXXKg PRESENT LOAD XXXXXKg PRES. ST.AXL. XXXXXKg LOAD-CENTER XXX.XXm 005119 CALIBR SCALE 6(7) LOAD SENSOR BOOM XX EXTENDED LE RI CALIBR XXXX XXXX PRESENT XXXX XXXX