10 8 Control system – 8.2.1.3 Electrical overloading system 8.2.1.3 Electrical overloading system page Electrical overloading system, function description 1 2 This overloading system is a part of the control system and performs calculations of the load with sensor values for boom length, boom angle and cylinder pressure in the lift cylinders. The calculated load and the measured distance from the machine is compared to a load curve, if the load is outside permitted distance the overloading system is activated. In case of overloading forward the control system interrupts the functions lift and lower as well as extension.
Using the by-pass, lower and extension can be activated to get out of the overload- ing situation. In case of overloading on the steering axle the control system activates a warning for overloading on the steering axle. Depending on how big the load is on the steering axle, the ma- chine's speed is limited. A bar in the event menu shows the range of the limitation. NOTE In case of overloading on the steering axle it is up to the op- erator to be careful when operating, no functions are inter- rupted. To reduce the load and regain full operational speed, the boom shall be lowered or extended. 3 000582 1. Sensor boom angle (R771) 2. Sensor boom length (R777) 3.
Sensor hydraulic pressure lift cylinder (B768-10, - 11, -12, -13) 6 D795 3 4 D797-R D797-F D793 2 7 m D 1 004889 D D D 5 Pa Pa 1. Sensor hydraulic pressure lift cylinder left (B768-10 and B768-11) as well as Sensor hydraulic pressure lift cylinder right (B768-12 and B768-13) 5. Sensor boom angle (R771) 2. Control unit frame front (D797-F) 6. Control unit KID (D795) 3. Sensor boom length (R777) 7. Control unit transmission (D793) 4. Control unit frame rear (D797-R) UDRF01.04GB Maintenance manual DRF 400–450