9 Frame, body, cab and accessories – 9.4.9 Humidity filter 19 page Humidity filter, changing WARNING Personal injury, environmental damage Read the safety instructions for refrigerant, see sec- tion B Safety . 1 Machine in service position, see section B Safety . 2 Drain the air conditioning of refrigerant R134a, with the intend- ed draining equipment. IMPORTANT Working on the air conditioning requires special au- thorization. 3 Disconnect hoses and cabling from the humidity filter. 4 Remove the humidity filter pressure switch from the humidity filter. 5 Change the humidity filter. 6 Fit the pressure switch and connect the hoses to the humidity filter.
7 Check for leaks and refill the machine with refrigerant R134a, with the intended equipment. For volume, see section section F Technical data . UDRF01.04GB Maintenance manual DRF 400–450