10 11 Common electrics – 11.5 Distribution of electricity 11.5 Distribution of electricity page Distribution of electricity, description This section describes the distribution of electric power and commu- nication between the control units. The distribution of electric pow- er describes the basics of the electrical system and the network of control units. 11.5.1 Voltage feed page Start-up of electrical system, description When the machine isn’t in use, the electrical system is in a power- less mode, that is, neither power electronics nor controls units are supplied with voltage. When the machine is started, voltage feed is activated and the redundant CAN bus is initiated.
Start-up is handled by control unit cab (D790-1). The first pre-requisite for the machine to be able to perform any ac- tion is to first establish the redundant voltage feed for control units and then establish CAN-bus communication to administer control signals for functions. Control units establish communication when: Operator’s door is opened Interior lighting is lit Flashing hazard lights are activated Start key in position I Start-up The following takes place at start-up: 1. Start-up signal to Control unit cab (D790-1). D791-2 (D791-3 / D791-4) 2. Control unit cab (D790-1) initiates connection of redundant volt- age feed.
See Redundant voltage feed of control units, descrip- tion page 12 . Startup signal D791 D790-1 D790-2 D795 D797-F D797-R D797-O 000036 Start-up signal is sent UDRF01.04GB Maintenance manual DRF 400–450