Kaiyi UDRF01.04GB — 11.5.1 Voltage feed

11 Common electrics – 11.5.1.1 Battery voltage (30) 11 KDU Attachment (option) 3. Control unit cab (D790-1) establishes of redundant CAN-bus. See Redundant CAN-bus, description page 16 . KDU Attachment 4. Control unit cab (D790-1) activates ignition voltage (15). See Ig- nition voltage (15), description page 13 . D790-1 D790-2 D795 5. Control unit cab (D790-1) activates CAN-bus drivetrain. See CAN-bus drivetrain, description page 16 . 6. Control unit cab (D790-1) activates manoeuvre switch voltage (15E). See Manoeuvre switch voltage (15E), description page 14 .

D797-F D797-R D797-O 000037 Redundant CAN-bus communication System down in powerless mode The system goes down in powerless mode when: Start key in position 0 and hold circuit's run time has expired and Start key in position 0 and no activity signal has been sent. no activity signal has been sent. Start key in position 1 and automatic engine shut-down has been activated. The following takes place when the system goes down in powerless mode. 1. Control unit cab (D790-1) cuts off manoeuvre switch volt- age(15E). See Manoeuvre switch voltage (15E), description page 14 . 2. Control unit cab (D790-1) cuts off ignition voltage (15). See Ignition voltage (15), description page 13 . 3.

Redundant voltage feed to control units is cut off. 4. Control unit cab (D790-1) disconnects the redundant CAN bus. See Redundant CAN-bus, description page 16 . 5. Control unit cab (D790-1) disconnects redundant voltage feed. See Redundant voltage feed of control units, description page 12 . 6. Control unit cab (D790-1) awaits start-up signal. Other electron- ics are without electric power. 11.5.1.1 Battery voltage (30) page Battery voltage 30-voltage, description The battery voltage feeds voltage: Control and monitoring system at start up. See Start-up of elec- trical system, description page 10 .

Starter motor Main relays (15-voltage) Control breaker relays (15E-voltage) Engine Transmission UDRF01.04GB Maintenance manual DRF 400–450