Kaiyi UDRF01.04GB — 11.5.1 Voltage feed

12 11 Common electrics – 11.5.1.2 Redundant voltage feed of control units 11.5.1.2 Redundant voltage feed of control units page Redundant voltage feed of control units, description A The redundant voltage feed only supplies the control units' control logic and buses, and is completely controlled by Control unit cab (D790-1). The control units' outputs remain without electric power and are first supplied with voltage when the ignition voltage is acti- vated. D791-2 Startup signal D791 D790-1 D790-2 D795 The redundant voltage feed for each control unit is independent of the other control units.

If a control unit is non-functional, it does not interfere with the voltage feed to the other control units. D797-F D797-R D797-O When all control units have redundant voltage feed and bus commu- nication, the system is ready to receive, process signals. B When redundant voltage feed is activated the following takes place. D791-2 1. Start-up signal is sent to Control unit cab (D790-1), see A in illus- tration. D791 2. A hold circuit is activated in Control unit cab (D790-1) which ac- tivates the control unit's control logic. D790-1 D790-2 D795 3. Control unit cab (D790-1) activates redundant voltage feed to the other control units, see B in illustration.

D797-F D797-R D797-O 000031 Control unit cab (D790-1) has 4 outputs for voltage feed, other control units have two inputs for redundant voltage feed. In case of malfunction of one feed, the control unit is supplied from the other feed. A. Start-up signal is sent B. All control units are supplied with voltage UDRF01.04GB Maintenance manual DRF 400–450