32 D Error codes – 1 Engine UDRF01.04GB Maintenance manual DRF 400–450 Descrip- tion Limitation Action Con- nec- tion and com- po- nent Diag- nostic menu Function group Code Cum- mins code 630/2 341 Software er- ror control unit engine (D794). Reduced en- gine power, engine difficult to start or en- gine stops. Reprogram software in Control unit engine (D794). - - 11.5.3.10 Control unit engine 632/3 255 Electric mal- function sole- noid valve fuel shut-off, cable short- circuited to voltage. No limitation. Check cabling between Control unit and compo- nent. Check component.
D794/ Actua- tor:33 - 1.2 Fuel sys- tem 632/4 254 Electric mal- function sole- noid valve fuel shut-off, cable short- circuited to ground. Engine is shut off. Check cabling between Control unit and compo- nent. Check component. D794/ Actua- tor:33 - 1.2 Fuel sys- tem 639/ 13 286 Communica- tion error with Control unit engine (D794), configuration error. - Use diagnostic menu to lo- calize incorrect segment - CAN/ POWER, menu 2 1.9 Control system en- gine 639/2 426 Communica- tion error with Control unit engine (D794). Functions via CAN-bus not working.
Use diagnostic menu to lo- calize incorrect segment - CAN/ POWER, menu 2 1.9 Control system en- gine 639/9 427 Communica- tion error with Control unit engine (D794). Functions via CAN-bus not working. Use diagnostic menu to lo- calize incorrect segment - CAN/ POWER, menu 2 1.9 Control system en- gine 639/9 285 Communica- tion error with Control unit engine (D794), time-out er- ror. - Use diagnostic menu to lo- calize incorrect segment - CAN/ POWER, menu 2 1.9 Control system en- gine