D Error codes – 1 Engine 31 UDRF01.04GB Maintenance manual DRF 400–450 Descrip- tion Limitation Action Con- nec- tion and com- po- nent Diag- nostic menu Function group Code Cum- mins code 620/3 227 Electric mal- function refer- ence voltage to sensor short- circuited to voltage. Reduced en- gine power. No warning for low oil pres- sure or low coolant level. Check cabling between Control unit and compo- nent. Check component. D794/ Sen- sor:18, Sen- sor:25, Sen- sor:45 - 1.7.8 Make- contact cool- ant level 1.8.3 Sensor oil pressure 1.8.7 Sensor oil tempera- ture 620/4 187 Electric mal- function refer- ence voltage to sensor short- circuited to ground. Reduced en- gine power.
No warning for low oil pres- sure or low coolant level. Check cabling between Control unit and compo- nent. Check component. D794/ Sen- sor:18, Sen- sor:25, Sen- sor:45 - 1.7.8 Make- contact cool- ant level 1.8.3 Sensor oil pressure 1.8.7 Sensor oil tempera- ture 626/ 11 381 Electric mal- function of control of re- lay preheat- ing. Preheating not working. Risk of white smoke Check cabling between Control unit and compo- nent. Check component. D794/ Actua- tor:34 EN- GINE, menu 5 1.10.1 Pre- heating 627/2 434 Voltage feed to control unit disappears without igni- tion off. Reduced en- gine power, engine difficult to start or en- gine stops. Check fuses. Check batteries and alter- nator.
D794/ OEM:7, OEM:8, OEM:17 , OEM:18 , OEM:28 - 11.5.1.3 Igni- tion voltage (15) 629/ 12 111 Internal error Control unit engine. Engine doesn't start. - - - 1.9 Control system en- gine 629/ 12 343 Internal error Control unit engine. - - - - 11.5.3.10 Control unit engine 630/ 12 346 Software er- ror control unit engine (D794). - - - - 11.5.3.10 Control unit engine