D Error codes – 2 Transmission 39 mm mm mm mm 2 Transmission page Error codes transmission In case of serious transmission malfunctions the control unit uses two modes with reduced functionality to protect the transmission against damage, Limp-home mode and Shut-down mode. For more detailed description see section 2 Transmission , group 2.8 Control system transmission . UDRF01.04GB Maintenance manual DRF 400–450 Description Limitation Action Con- nec- tion and compo- nent Diag- nostic menu Function group Code Dan a code 00.50 00.50 Memory error in control unit transmission. Transmission in locked neutral po- sition (Shut-down mode).
Contact Kalmar In- dustries AB for more information - - 11.5.3.9 Con- trol unit trans- mission 00.51 00.51 Memory error in control unit transmission. Transmission in locked neutral po- sition (Shut-down mode). Contact Kalmar In- dustries AB for more information - - 11.5.3.9 Con- trol unit trans- mission 00.52 00.52 Memory error in control unit transmission. Transmission in locked neutral po- sition (Shut-down mode). Contact Kalmar In- dustries AB for more information. - - 11.5.3.9 Con- trol unit trans- mission 00.53 00.53 Memory error in control unit transmission. Transmission in locked neutral po- sition (Shut-down mode). Contact Kalmar In- dustries AB for more information.
- - 11.5.3.9 Con- trol unit trans- mission 20.60 20.60 Signal from sen- sor oil pressure indicates low oil pressure when there should be pressure. Transmission in locked neutral po- sition (Shut-down mode). Check cabling to sensor oil pres- sure. Check sensor oil pressure (with en- gine on/off). D793/A:2 - B253 TRANSM , menu 10 2.6.2 Sensor oil pressure 20.61 20.61 Signal from sen- sor oil pressure indicates low oil pressure when there should be pressure. Transmission in locked neutral po- sition (Shut-down mode). Check cabling to sensor oil pres- sure. Check sensor oil pressure (with en- gine on/off). D793/A:2 - B253 TRANSM , menu 10 2.6.2 Sensor oil pressure