Kaiyi UDRF01.04GB — Error codes transmission

44 D Error codes – 2 Transmission UDRF01.04GB Maintenance manual DRF 400–450 Description Limitation Action Con- nec- tion and compo- nent Diag- nostic menu Function group Code Dan a code 54.00 54.00 Analogue input 4 short- circuited to ground. - - D793/ M1- S221 - 2.7.2 Sensor oil tempera- ture 54.01 54.01 Analogue input 4 not connect- ed. - - D793/ M1- S221 - 2.7.2 Sensor oil tempera- ture 55.00 55.00 Analogue input 5 short- circuited to ground. - - D793/P1 - - 55.01 55.01 Analogue input 5 not connect- ed. - - D793/P1 - - 56.00 56.00 Analogue input 6 short- circuited to ground. - - D793/S1 - - 56.01 56.01 Analogue input 6 not connect- ed.

- - D793/S1 - - 60.00 60.00 Sensor drum rpm short- circuited to ground. When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component. Check component. D793/C3 - B752 TRANSM , menu 6 2.3.6. Sensor rpm drum