Kaiyi UDRF01.04GB — Error codes transmission

D Error codes – 2 Transmission 45 UDRF01.04GB Maintenance manual DRF 400–450 Description Limitation Action Con- nec- tion and compo- nent Diag- nostic menu Function group Code Dan a code 60.01 60.01 Sensor rpm drum not con- nected. When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component. Check component. D793/C3 - B752 TRANSM , menu 6 2.3.6. Sensor rpm drum 61.00 61.00 Sensor rpm out- put shaft short- circuited to ground.

When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component. Check component. D793/D3 - B758 TRANSM , menu 6 2.3.8 Sensor rpm output shaft 61.01 61.01 Sensor rpm out- put shaft not connected. When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component.

Check component. D793/D3 - B758 TRANSM , menu 6 2.3.8 Sensor rpm output shaft