Kaiyi UDRF01.04GB — Error codes transmission

46 D Error codes – 2 Transmission UDRF01.04GB Maintenance manual DRF 400–450 Description Limitation Action Con- nec- tion and compo- nent Diag- nostic menu Function group Code Dan a code 62.00 62.00 Sensor engine rpm short- circuited to ground. When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component. Check component.

D793/F3 - B758/ 766 TRANSM , menu 6 2.2.5 Sensor engine rpm and oil tem- perature transmission 62.01 62.01 Sensor engine rpm not con- nected or open circuit. When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component. Check component. D793/F3 - B758/ 766 TRANSM , menu 6 2.2.5 Sensor engine rpm and oil tem- perature transmission 63.00 63.00 Sensor rpm tur- bine short- circuited to ground.

When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component. Check component. D793/R2 - B751 TRANSM , menu 6 2.3.5. Sensor turbine