D Error codes – 2 Transmission 47 UDRF01.04GB Maintenance manual DRF 400–450 Description Limitation Action Con- nec- tion and compo- nent Diag- nostic menu Function group Code Dan a code 63.01 63.01 Sensor turbine not connected. When only one rpm signal which isn't the engine rpm signal is in- correct, the con- trol unit calculates the missing rpm. If several rpm sig- nals or the engine rpm signal is in- correct the con- trol unit activates, Limp home mode. Check cabling be- tween Control unit and component. Check component. D793/R2 - B751 TRANSM , menu 6 2.3.5.
Sensor turbine 70.00 70.00 Electric mal- function sole- noid valve forward, cables are short- circuited to each other, sig- nal cable short- circuited to voltage or posi- tive cable short- circuited to ground. Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve for- ward (Y630). D793/B1 - Y630, C1 - Y630 TRANSM , menu 8 2.3.4 Valve block trans- mission con- trol 70.01 70.01 Electric mal- function sole- noid valve forward or short-circuited voltage . Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve for- ward (Y630). Check solenoid valve forward (Y630).
D793/B1 - Y630, C1 - Y630 TRANSM , menu 8 2.3.4 Valve block trans- mission con- trol 70.02 70.02 Electric mal- function sole- noid valve forward, control current above 1400mA. Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve for- ward (Y630). Check solenoid valve forward (Y630). D793/B1 - Y630, C1 - Y630 TRANSM , menu 9 2.3.4 Valve block trans- mission con- trol