D Error codes – 2 Transmission 49 UDRF01.04GB Maintenance manual DRF 400–450 Description Limitation Action Con- nec- tion and compo- nent Diag- nostic menu Function group Code Dan a code 72.00 72.00 Electric mal- function re- verse (Analogue output signal 2), cables short- circuited to each other, sig- nal cable short- circuited to voltage or posi- tive cable short- circuited to ground. Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve re- verse (Y631). D793/F1 - Y631, G1 - Y631 TRANSM , menu 8 2.3.4 Valve block trans- mission con- trol 72.01 72.01 Electric mal- function sole- noid valve reverse, open circuit or short- circuited volt- age.
Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve re- verse (Y631). Check solenoid valve reverse (Y631). D793/F1 - Y631, G1 - Y631 TRANSM , menu 8 2.3.4 Valve block trans- mission con- trol 72.02 72.02 Electric mal- function sole- noid valve reverse, con- trol current above 1400mA. Control unit acti- vates, Limp-home mode. Check cabling to solenoid valve re- verse (Y631). Check solenoid valve reverse (Y631). D793/F1 - Y631, G1 - Y631 TRANSM , menu 9 2.3.4 Valve block trans- mission con- trol 72.03 72.03 Electric mal- function sole- noid valve reverse, con- trol current out- side approved interval (incor- rect imped- ance). Control unit acti- vates, Limp-home mode.
Check cabling to solenoid valve re- verse (Y631). Check solenoid valve reverse (Y631). D793/F1 - Y631, G1 - Y631 TRANSM , menu 9 2.3.4 Valve block trans- mission con- trol