Kaiyi UDRF01.04GB — Error codes machine

D Error codes – 8 Control system 57 UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 27 Interference during software download – Turn the ignition off and on. Perform software down- load again. D794 – 11.5.3.10 Control unit engine 28 Interference during software download – Turn the ignition off and on. Perform software down- load again. D794 – 11.5.3.10 Control unit engine 29 Interference during software download – Turn the ignition off and on. Perform software down- load again. D794 – 11.5.3.10 Control unit engine 30 Interference during software download – Turn the ignition off and on.

Perform software down- load again. D794 – 11.5.3.10 Control unit engine 31 Voltage feed to Control unit cab (D790-1) below 18 V or above 32 V. Controls in cab not working. Check fuse F58-4:1. Check cabling between the control unit and component with diagnostic menu. Check component. D790-1/ K1:2, K1:3, K1:4 CAN/ POWER, menu 6 11.5.1.3 Igni- tion voltage (15) 32 5 V feed voltage to control below 4.9 V or above 5.1 V. Certain con- trols in the cab do not work. Check cabling between the control unit and component with diagnostic menu. Check component.

D790-1/ K4:5, K 5:1, K17:2, K 9:7, K10:3 CAN/ POWER, menu 6 11.5.3.1 Con- trol unit cab 33 No feed of control breaker voltage to control unit cab from battery. Control breaker can- not be re- leased. All hydraulic functions are blocked. Check fuse F58-3:8. Check cabling between the control unit and component with diagnostic menu. D790-1/ K11:13 – K2 CAN/ POWER, menu 5 11.5.1.4 Con- trol switch voltage (15E) 34 Signal error from Switch parking brake, indicates re- leased or applied at same time or noth- ing at all. Parking brake cannot be released. Check cabling between the control unit and component with diagnostic menu. Check component.

D791-1/ K8:5 - S107, K8:13 - S107 HYD, menu 5 4.1.2 Parking brake control