60 D Error codes – 8 Control system UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 66 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Washer mo- tor (M651). Windshield washer not working. Check the wiring to the washer motor. D790-1/ K10:13 – M651 CAB, menu 1 9.5.4 Washer motor and reservoir 67 Transistor has been triggered due to short circuit or open circuit in circuit for Wiper motor, roof (M650-3). Wiper roof not working. Check the wiring to wiper motor, roof.
D790-1/ K10:14 – M650-3 CAB, menu 4 9.5.6 Wiper motor roof 70 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for interior lights cab (H434). Interior lights cab not working. Check bulbs for interior lighting, change if needed. Check the wiring to interior lighting. D790-1/ K11:5 – H434 LIGHTS, menu 12 9.6.13 Interior lighting cab 80 No signal from Pres- sure switch air con- ditioning (S246). Air condi- tioning not working. Check drive belt for com- pressor for air conditioning. Check that compressor for air conditioning is activated. Check signals and cabling with diagnostic menu.
D797-R/ K1:23 – S246 CLI- MATE, menu 3 and CLI- MATE, menu 2 9.4.10 Pres- sure monitor 81 Incorrect position signal from Damper motor (Y672). Air distribu- tion cannot be changed. Check cabling between the control unit and component with diagnostic menu. Check component. D790-1/ K4:7 – Y672 CLI- MATE, menu 4 9.4.6 Fresh air and recircula- tion damper 82 Signal error from Control fan speed (R8082). Cab fan not working. Check cabling between the control unit and component with diagnostic menu. Check component. D790-1/ K5:7 – R8082 CLI- MATE, menu 5 9.1.4 Control fan 83 Signal error from Control for temper- ature (R8083). The temper- ature is set to 22 °C.
Check cabling between the control unit and component with diagnostic menu. Check component. D790-1/ K5:8 – R8083 CLI- MATE, menu 5 9.1.6 Control heating 84 Signal error from Control for air distri- bution (R8084). Air distribu- tion cannot be changed. Check cabling between the control unit and component with diagnostic menu. Check component. D790-1/ K5:9 – R8084 CLI- MATE, menu 5 9.1.7 Control air distribu- tion