Kaiyi UDRF01.04GB — Error codes machine

62 D Error codes – 8 Control system UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 98 Signal error from Sensor temperature outlet fan (B775-2). Air condi- tioning not working. Check cabling between the control unit and component with diagnostic menu. Check component. D790-1/ K4:10 – B775-2 CLI- MATE, menu 2 9.4.16 Sensor temperature outlet fan 99 Signal error from Sensor temperature refrigerant (B775-3). Air condi- tioning not working. Check cabling between the control unit and component with diagnostic menu. Check component.

D790-1/ K4:11 – B775-3 CLI- MATE, menu 2 9.4.12 Sensor temperature refrigerant 101 Redundant voltage feed left to control unit frame front (D797-F) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. D797-F/ K2:7 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 102 Redundant voltage feed right to control unit frame front (D797-F) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. D797-F/ K2:8 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 103 Voltage feed to Control unit frame front (D797-F) be- low 18 V or above 32 V.

– Check fuse F58-2:1, change if needed. Check cabling between the control unit and component with diagnostic menu. D797-F/ K2:1/9/10 CAN/ POWER, menu 8 11.5.1.3 Igni- tion voltage (15) 104 Incorrect control breaker voltage to Control unit frame front (D797-F) Control breaker can- not be re- leased. All hydraulic functions blocked. Check fuse F58-3:2, change if needed. Check cabling between the control unit and component with diagnostic menu. Check component. D797-F/ K2:11 CAN/ POWER, menu 8 11.5.1.4 Con- trol switch voltage (15E) 105 5 V supply voltage to sensor below 4.9 V or above 5.1 V. – Check cabling between the control unit and component with diagnostic menu. Check component.

D797-F/ K1:8 CAN/ POWER, menu 9 11.5.3.2 Con- trol unit frame front 106 Incorrect values for load curve. Lift and low- er as well as extension not working. Contact Kalmar Industries AB – – 7.2 Lift and lower 7.3 Ex- tension