D Error codes – 8 Control system 63 UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 110 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Cooling fan, brake oil (M674). Cooling fan brake oil not working. Check light. Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D797-F/ K1:14 – M674 HYD, menu 2 4.8.9 Cooling fan 111 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for High beam light left (H402L). Left high beam not working. Check light.
Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D797-F/ K1:1 – H402L LIGHTS, menu 6 9.6.2 High beams 112 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for High beam light right (H402R). Right high beam not working. Check light. Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D797-F/ K1:15 – H402R LIGHTS, menu 6 9.6.2 High beams 113 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for central lu- brication unit (M693-1). Central lubri- cation ma- chine not working. Check cabling between the control unit and component with diagnostic menu.
Check component. D797-F/ K1:28 - M693-1 CAB, menu 9 9.14.1 Pump unit 114 Transistor has been triggered due to short circuit or open circuit in circuit for low beams (H400L/ H400R) Low beams not working. Check cabling between the control unit and component with diagnostic menu. Check component. D797-F/ K1:42 – H400L/ H400R LIGHTS, menu 6 9.6.1 Low beams 115 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for solenoid valve boom up (Y6005). Lift not work- ing. Check cabling between the control unit and component with diagnostic menu. Check component. D797-F/ K1:2 – Y6005 BOOM, menu 4 7.2.3 Control valve lift, low- er and exten- sion