68 D Error codes – 8 Control system UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 144 High brake oil tem- perature. Reduced braking per- formance. Check that the cooling fan works. Check that cooler isn't clogged. Check cabling between the control unit and component with diagnostic menu. – HYD, menu 2 4.8 Tempera- ture control, cleaning and brake oil 145 Unreasonable val- ue Sensor brake oil temperature (B762). – Check that the cooling fan works. Check that cooler isn't clogged. Check cabling between the control unit and component with diagnostic menu.
D797-F/ K2:13 – B762 HYD, menu 2 4.8.10 Sensor brake oil tem- perature 150 Malfunction in over- load protection. Overload protection not working. All lift func- tions oper- ate at reduced speed. Check if there are error codes for sensors in the overload system. Check components and wiring with diagnostic menu. – OP, menu 1 – 5 8.2.1 Over- load system 151 Redundant voltage feed left to control unit frame rear (D797-R) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component.
D797-R/ K2:7 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 152 Redundant voltage feed right to control unit frame rear (D797-R) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. D797-R/ K2:8 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 153 Voltage feed to Control unit frame rear (D797-F) below 18 V or above 32 V. – Check fuse F58-2:3, change if needed. Check cabling between the control unit and component with diagnostic menu. D797-R/ K2:1/9/10 CAN/ POWER, menu 8 11.5.1.3 Igni- tion voltage (15)