76 D Error codes – 8 Control system UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 251 Redundant voltage feed left to Control unit attachment (D971-1) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K2:7 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 252 Redundant voltage feed left to Control unit attachment (D791-1) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component.
D791-1/ K2:8 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 253 Control breaker voltage to Control unit attachment (D791-1) below 18 V or above 32 V. – Check fuse F58-3:1, change if needed. Check cabling between the control unit and component with diagnostic menu. D791-1/ K2:1/9/10 CAN/ POWER, menu 8 11.5.1.4 Con- trol switch voltage (15E) 254 Incorrect control breaker voltage to Control unit attach- ment (D791-1) Control breaker can- not be re- leased. All hydraulic functions blocked. Check fuse F58-3:1, change if needed. Check cabling between the control unit and component with diagnostic menu.
D791-1/ K2:11 CAN/ POWER, menu 8 11.5.1.4 Con- trol switch voltage (15E) 260 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for central unit central lubrication (M693-2). Central lubri- cation at- tachment not working. Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K1:14 – M693-2 CAB, menu 10 9.14.1 Pump unit 261 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for light work light attachment right (H406R-2). Work light at- tachment right not working. Check cabling between the control unit and component with diagnostic menu. Check component.
D791-1/ K1:1 – H406R-2 LIGHTS, menu 2 9.6.12 Work light attach- ment 262 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for light work light attachment left (H406L-2). Work light at- tachment left not working. Check light. Check cabling between the control unit and component with diagnostic menu. Check bulb socket. D791-1/ K1:15 – H406L-2 LIGHTS, menu 2 9.6.12 Work light attach- ment