Kaiyi UDRF01.04GB — Error codes machine

80 D Error codes – 8 Control system UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 290 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for solenoid valve Spreader in (Y6019) Spreader not working. Check cabling between the control unit and component with diagnostic menu. Check component. D791-1/ K1:19 – Y6019 ATTACH, menu 12 7.5.3 Control valve attach- ment 298 Sensor twistlock in- dicates that twist- lock left is between open and locked position. Lift and ex- tension not working. Check that Sensors twist- lock are clean and correctly adjusted.

Check cabling between the control unit and component with diagnostic menu. – ATTACH, menu 8 7.9.1.9 Sensor twistlock 299 Sensor twistlock in- dicates that twist- lock right is between open and locked position. Lift and ex- tension not working. Check that Sensors twist- lock are clean and correctly adjusted. Check cabling between the control unit and component with diagnostic menu. – ATTACH, menu 8 7.9.1.9 Sensor twistlock 300 Sensor alignment indicates unreason- able distance. Twistlock not working. Check that Sensors align- ment are clean and correct- ly adjusted. Check that alignment pin runs smoothly. Check cabling between the control unit and component with diagnostic menu.

– ATTACH, menu 8 7.9.1.8 Sensor alignment 301 Redundant voltage feed left to Control unit attachment (D971-2) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. D791-2/ K2:7 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units 302 Redundant voltage feed left to Control unit attachment (D791-2) does not arrive. – Check cabling between the control unit and component with diagnostic menu. Check component. D791-2/ K2:8 CAN/ POWER, menu 8 11.5.1.2 Re- dundant volt- age feed of control units