Kaiyi UDRF01.04GB — Error codes machine

D Error codes – 8 Control system 81 UDRF01.04GB Maintenance manual DRF 400–450 Code Description Limitation Action Connec- tion and compo- nent Diag- nostic menu Function group 303 Emergency voltage to Control unit at- tachment (D791-2) below 18 V or above 32 V. Control breaker can- not be re- leased. All hydraulic functions blocked. Check fuse F58-3:1, change if needed. Check cabling between the control unit and component with diagnostic menu. D791-2/ K2:1/9/10 CAN/ POWER, menu 8 11.5.1.4 Con- trol switch voltage (15E) 304 Incorrect control breaker voltage to Control unit attach- ment (D791-2) Control breaker can- not be re- leased. All hydraulic functions blocked.

Check fuse F58-3:1, change if needed. Check cabling between the control unit and component with diagnostic menu. D791-2/ K2:11 CAN/ POWER, menu 8 11.5.1.4 Con- trol switch voltage (15E) 315 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Solenoid valve levelling right (Y6035). Levelling not working. Check cabling between the control unit and component with diagnostic menu. Check component. D791-2/ K1:2 – Y6035 ATTACH, menu 17 7.8.3 Control valve attach- ment 316 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Solenoid valve levelling left (Y6036). Levelling not working.

Check cabling between the control unit and component with diagnostic menu. Check component. D791-2/ K1:3 – Y6036 ATTACH, menu 18 7.8.3 Control valve attach- ment 317 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Solenoid valve tilt out (Y6010). Controllable tilt not work- ing. Check cabling between the control unit and component with diagnostic menu. Check component. D791-2/ K1:4 – Y6010 ATTACH, menu 14 7.7.5 Control valve attach- ment 318 Transistor has been triggered due to short-circuit or open circuit in cir- cuit for Solenoid valve tilt in (Y6011). Controllable tilt not work- ing.

Check cabling between the control unit and component with diagnostic menu. Check component. D791-2/ K1:5 – Y6011 ATTACH, menu 15 7.7.5 Control valve attach- ment