Kaiyi UDRF01.04GB — Troubleshooting, general work instructions

4 0 Complete machine – Complete machine page Troubleshooting, general work instructions When troubleshooting, it’s important that the work is structured and logical. The point of the troubleshooting described in the mainte- nance manual is to exclude components as error source so that the real error source can be pin-pointed. A proposal for structured work method is described below. When troubleshooting, it’s important to understand how the ma- chine functions, certain malfunctions can be pin-pointed directly us- ing function descriptions. In the sections 0–12 there are descriptions of the machine’s different functions.

Troubleshooting procedure 1 Check that there is battery voltage available. Battery disconnect switch, must be in position 1. Battery voltage, should be 22–30 V. Fuses, check that they are intact. 2 Check that all oil and fluid levels are normal. Fuel Engine oil Transmission oil Oil for brake system Hydraulic oil Coolant Washer fluid 3 Check if there are error codes. 4 If there are error codes, use the error code lists as a guide. See Troubleshooting with error code, example page 5 . In the error code lists there are recommended actions for every error code. Error code lists are found in section D Error codes .

5 If there is no error code, or problem remains, use the function description for function in question in section 0–12 . In the function description there’s information about which components are involved in the function and how these com- ponents work together. In certain cases, there’s information about which conditions apply to enable activation of the func- tion. Measuring points are marked with flags (C for pressure check connections, D for diagnostic menu). UDRF01.04GB Maintenance manual DRF 400–450