PIPER COMANCHE SERVICE MANUAL '7 A-S. Removal.Of Eapae Cow lin,. (PA-.z~260. Serial Nos. 24-4183 and 24-4804 and up.) a. Ascertain that the master switch and maeneto switches arc in the off position. b. Releue the three cowl fastenm on each side of the eqine coml>artnlent. c. Remove attaching screws from the tal>cowl at the f&feW.n. d. Remove attachinJ screws from the note lec:tion l>artinI sur.aces. e. Remove the twO attachin, nuts, wuhen and screws -curinI the top cowl cbannel to fucwall. f. Lift the tOp cowl from the engine usembly. I. Disconnect nose gear door ae:tUatifti rods. h. Disconnect cowl flap control cables. 1.
Disconnect gear door fnmcchanncls frem fuewall and attachment straps by removing screws. j. DisconneCt dn.in lines €rom bottom cowl. k. Remove bottom cowl by rcmovinl SCftWS sccurin, it to the firewall. '7 A-9. Cleanm,. Inspection And Rep .. Of EDpe Cow lin, . .t. Clean cowliftl with a suitable c!caninl solvent and wipe dry with a clean cloth. b. Inspect cowling for dents. cracks, loose rivets. elonptcd holes and damapd or missing fureners_ c. Repair all defects to prevent further damacc. Fibcqlus tcl>air procedures may be accomplished according to Fiberglass Repain, Section IV. iA-10. InsWIation Of Enpne Cowtint. (PA·2~260. Serial Nc,. 24-4783 and 2~04 and up.) a.
Position the bottom cowlinl and secutC with ICt'CWS to the fltewall bulkhead. b. Secure the gear door frame channels to the fuewall and ename mount maps using attaching screws. c. Connect cowl nap conttol cables to flap acruatin, arms. d. Connect gear door acruatina rods to doors. e. Connect drain cubes to outlet in bottom cowl. f. Position tOPcowl on enaine assembly. I. Attach the cowl support channels to the fltewall with screws, washers and nuts. h. Secure the cowl nose section halves with screws. 1. Secure top cowl to firewall bulkhead with screws. ). .~djust nose gear door. (Refer to SeCtion IV.) k, Secure side panels with fasteners. i A·ll. Propeller.
CAUTION Seiore performing any service functions on the propeller. ucertaln that the master switch is "OFF", the rnaplCfO switches are "OFF" and the mixture concrol is in the "IDLE Ct'ToOFF" position. POWER PLANT ISSUED: 8/18/72 2 C5