PIPER COMANCHE SERVICE MAl'il"Al 7A-77. Removal Of Harness. a. Disconnect the clamps that secure the wires to the engine and accessories. b. Loosen the coupling nuts at the spark plugs and remove the insulators from the spark plug barrel well. lse caution when withdrawing the insulator not to damage the insulator spring. c. Place a guard over the harness insulator. d. Remove the harness assembly terminal plate from the magneto. e. Remove the engine baffle plate that receives the harness asernbly. f. Remove the harness from the airplane. 7/\.78. Installation or Harness. Before installing harness on magneto. checking mating surfaces for cleanliness.
Spray entire face of grommet with a light coat of Plastic Mold Spary. SM-O-O-TH Silicone Spray or equivalent. This will prevent harness grommet from sticking to magneto distributor block. a. Place the harness terminal plate on the magneto and tighten nuts around the plate alternately to seat cover squarely on magneto. Torque screws to 18 to 22 inch pounds. b. Route ignition wires to their respective cylinders. c. Clamp the harness assembly in position and replace the engine baffle plate. d. Connect the leads to the spark plugs. i/\-79. Spark Plugs. .. A-SO. Removal Of Spark Plugs. a.
Loosen the coupling nut on the harness lead and remove the terminal insulator from the spark plug barrel well. ~OTE When withdrawing the ignition cable lead connection from the plug care must be taken to pull the lead straight out and in line with the center line of the plug barrel: otherwise. a side load will be applied v. hich frequently results in damage to the barrel insulator and connector. If the lead cannot be removed easily in this matter. the resisting contact between the neoprene collar and the barrel insulator will be broken by a rotary twisting of the collar. Avoid undue distortion of the collar and possible side loading of the barrel insulator. h.
Remove the spark plug from the engine. In the course of engine operation. carbon and other combustion products will be deposited on the end of the spark plug and will penetrate the lower threads to some degree. As a result. greater torque is frequently required for removing a plug than for its installation. Accordingly. the torque limitations given do not apply to plug removal and sufficient torque must be used to unscrew the plug. The higher torque in removal is not as detrimental as in installation. since it cannot stretch the threaded section. It does. however, impose a shearing load of this section and may. if sufficiently severe. produce a failure in this location. ISS LED:
8/18/72 2E3 POWER PlA~T