PIPER COMANCHE SERVice MANUAL FIGURE 7A·23. REMOVING SEIZED SPARK PLUGS NOTE Torque indicatiDl handle should not be used for spark plug removal because of the greater torque requirement. c. Place spark plup in a aay that will identify their position in the engine as soon as they are removed. NOTE Spark plup should not be used if they have been dropped. d. Removal of sci&ed spark plup in the cylinder may be accomplished by application of liquid carbon dioxide by a Conical metal funnel adapter with a hole at the apex just latJc enough to accommodate the funnel of a C02 beetle. (Refer to Figure 7A·23.) When a seiled spark plUJ cannot be removed by normal means.
the funnel adapter is placed over and around the spark plug. Place the funnel of the C02 bottle inside the funnel adapter and rele:uc the carbon dioxid~ to chill and contract the spark plug. Break the spark plug leese with a wrencn. A warm cylinder head at the time the carbon dioxide is applied will ald in the removal of an excessively seized plu,. .. Do not allow foreign objects to enter the spark plUJ hole. POWER PLANT ISSUED: 8/18/72 2 E4