PIPER COMANCHE SERVICE MANUAL TABLE VlIA-IU. TROUBLISHOOTtNC CHART (ENCINE) (FUlL INJECTION) POWER PLANT ISSUED: 8/18/72 2 E13 TroulHc e.-. Remedy Failure of ellline to start. Luk offud. VndcrprilDiDl· Overpriminc. Incomct throttle seain. _ Defective spark plup. Dcfee:tiw battery. Improper operation of mapeto breaker poinu. Air bubbla in fuel system. File! pump fai1lltc. Fllel tiDe rauieted. Lack of sufficient fuel pressure. Internal failure. Cloacd injector nozzles. Defective ipition wire. Cbeck.fuel system for leaks. Fill f\lel tank. Clan dirty lina. stl'ainen or fuel cocks. ' Prime by boldiftl boost pllmp switch 4 to 10 seconds. Place control in "idle-cur- ofr·.
Open throttle and Wlload ellline by Nmin, over with SW'tCf Opcn throttle to 118 of irs L'&nJC. Clean and adjllStor replace spuk plUl or plup. Rcpl&ce with charged battery. Clean poiDa. Check internal timin. of magnetos. Check. fuel vent. Replace pump. Cbeck.inlet line. Check fuel strainer and fuel adjusanenu. Check. oil sump strainer for mr..alparticles. If found. complete overhaul of the enJine may be required. Remove from cylindcn. clean in acetone solvent. blow through the injector nozzle opposite direction of fuel flow with compressed air. 100 pSI. Check with electric tester. and replace any defective wires.