PIPER COMANCHE SERVIce MANUAL TABU VlIA-ID.TROUBLESHOOTING CHAJt.T (ENGINE) (FUEL INJECTOR) (conI:) POWER PlANT ISSUED: 8/18nZ 2 E14 Trouble ea.u.. Remedy Failure of enaiDe [I) idle pro9crly. Incorrect idle adjustment. Insufficient fuel prasure. CI"IPd injector nozzles. Leak in induction systCft'l. Low cylinder compression. Faulty' ipition system. Adju. throttle Stop to obtain correCt idle. Check fuel stniner and pump pressure adjustment. Remove and flush with acetone. Blow mroul" orifice with compressed air - 100 psi. Tilinen all connections in the induction system. Re- place any defective pans. Check condition of piston rings and valve scatS. Check entitc ipition system.

Low power and Ilnewn l"'Jnning. ,\tixture too ricb; indicated by slugish enJine epee- ation, red exbaust flame at niBhe.EXlRme cues indicated by b1&ck smoke from exhaust. Mixture tOO Ian; indicated by overhcatiq or back· firing. leaky noule. Cloged injeCtor nozzles. Dirt in inlet screen. Din in "T" fitting. Fuel supply pressure excessively high. Leak in mlilufoid line. InjeCtor may need recall· bration by authorized penonDel. Check fuel suppl~·. Check fuel lines for obstrUCtions or restrictions. Remove nozzle and blow intO it. Air escapin, throlllh the noule valve indicates leaking. Replace nozde. Remove and tlush with acetone. Slow through orifice with compressed air • 100 PSI.

Remove screen and :lllsh With acetone. Blow with compressed air. Remove "T" fitting lot dism- burer. clean in acetone. Blow through orifice With compressed air - 100 pSI. C~eck ruel pump pressure. Tighten fittings.