PIPER COMANCHE SERVICE MANUAL FIGURE lC·S. CONTACT POINTS g. Check condition of the am foUower felt. Squeeze felt updy between thumb and forefm,er. If fingers are not moistcnecl with oil, re-oil usiq Z or 3 drop. of Scintilla 10-865Z7 lubricant. Allow approximately 30 minutes for felt to absorb the oil. Blot off the exccu with a dean doth. Too much oil may foul contact poino and c:&1ISC excessivebllminJ. h. Check the capacitor mOllntir!t bracket for cncks or lootenesa. Usi", the Scintilla 11-176i-1. ·z or -3 Condenxr Testor or equiva1ent. check capacitor for capacitance. series resistance and leakate. Capacitance shall be at lean 0.30 microfarads. i, Check ma,ncto to enciDe timin, as foUows:
1. Connect Scintilla 11-851 TimiD( Litht or tquivalent aero. the main contact assembly. 2. Slowly brinf the engine up to number one cylinder advance finn, position as instructed in paragraph 7C-S 3. At this inSWlt the timin,li,ht should '0 out. If it does. the mapetO is properly timed to the engu'le. If the timinl litht does not go Ollt. removal of the mqfteto for internal timing check and inspection is recommended. NOTE The magneto service insmlctions in this manual are to cover minor repairs and timing. For further repairs and adjllStlheDts of the magneto, it is recommended that the manufacturer's recommended service instructions be followed. 2 H12 POWER PLANT ISSUED: 8/18/72 NORMAl.
POINT IS SMOOTH ~NO FUT. SURFACE HAS CULL GRAY "SANOElUSTEO" APPEARANCE MINOR IRREGUL.ARITIES - WEL.L. OEFINED MOUNO SMOOTH ROL.L.ING HIL.LS EXTENOING NOTICEABLY ANO OAL.ES WITHOUT ANY ABOVE SURROUND ING DEEP PITS OR HIGH PEAKS. SURFACE. Tl-IIS IS A NORMAL. CON- OITION OF POINT WEAR.