PIPER COMANCHE SERVICE MANUAL TABLE IX· VII. TROUBLeSHOOTING (cent) ELECTRICAL SYSTEM ISSUED: 8/18/72 Fl Troubl. Cau.e RemMY Generator operating within rated speed range but voltaae output low. (ceet) Shorted or open armaaue coils. -Improper operation of the voltace rel'llator. Replace ..nerator or arm· ature. Adjust reculator. Generator operating within rated speed ranle but voltmeter indicates zero. Wirinl not properly connected. Grounded or open field coil assembly. See electrical system wiring dialtam. Remove the leneritor and replace with one know:\ to be in load condition. Generator operating within rated speed ranle. but voltage output is erratic.
Unstable operation of the voltace reculator. Same as •'Generator operatin, within rated speed ranle but voltace OUtput low". above. Replace voltale reculator. Use remedy under' 'Gen· erator operating within rated ,pHd ranle but voltap eutput low". above. Excessive sparking at generator brushes. Same .. "Generator operatinl within rated speed ranle but volta,e outpUt low". above. Use remedy under "Generator operatine within rated speed ranae but voltage output low", above. I Generator operating within rated speed ranle but system am- meter reads off scale. Generator field mapetind in the wroal direction. Flash field with a Jumper wire on regulator between generator and battery.
System ammeter fluctuates excessively when in- dicating rated load. I 1 Generatine system is ever- loaded. Improper operation of pn- erator reverse·current relay. Loose connections. Check the system for abnormal loads. Readjust to operate properly. Ti&hten connections.