PIPER COMANCHE SERVICE MANUAL TABLE IX· VII. TROUBLESHOOTING (cont) ELECTRICAL SYSTEM ISSUED: 8/18/72 3 F2 Trouble Coule Remedy Burned-out system am- meter or line fuse. Discharged battery. Defective wiring. Replace with a fully charged battery. Replace all defective wiring. ALTERNATOR No output from alternator. Malfunction of alternator, alternator output circuit or field circuit. Check alternator output and field circuits. Refer to Paragraph 9-44. Check alternator. Refer to Paragraph 9-44. Reduced output from alternator. Open diode. Check alternator. Refer to Paragraph 9-44. STARTER Motor fails to operate. I I I i I Low battery charge. Defective or improper wiring or loose connections.
Defective starter solenoid or control switch. Binding. worn. or improperly seated brush, or brushes with excessive side play. Check and recharge if necessary. Refer to electrical wiring diagram and check all wiring. Replace faulty unit. Brushes should be a free fit in the brush boxes without excessive side play. Bind- ing brushes and brush boxes should be wiped clean with a gasoline (undoDed'\ moistened cloth.