PIPER COMANCHE SERVICE MANUAL The manifold preslUre Pille is a vapor proof. absolute pralUre type iDsaument. Prc:sIure from the intake manifold of the engine is transmiaed to the insauw.ent throups a line. A poinm indicates the manifold pressure available at the eftIine in inchG of merewy. The fuel pressure .allle is a diffemni&1 preaure inmwnalt compriJed of a diaphnpn seftSin, unit which sector aDd pinion movement to amplify diaphnpt 1IIOftIDalt. It is mounted ill the clulteT on the insaurnent panel On me PA-24-1BO the pup is co~ to the fuel sysran at the CIIIiDe driven file! pump. while on the PA·24-Z'O. -260, and -400 it is colUlCCtlCd at the carburetOr or injectOr fuel inlet finial.

The oil prnsure pup is mounted in the dutCf on the iDlmamcnt panel. This pup will indie:ue the amount of oil pressure available at the pralW'iRd CftJiDe oil puap. . 11-1. TroubiesboociD .. For tfOublcshootinc of the yaria,. iftstrumara. refer to the aoubleshoocina table at the end of this section. 11·8. RaDoYlll And ta.callacioD of 1Darumeaa. SiDce all i.utraaleaa are mounted in a similar manner, a description of & typical removal and installation is provided u a pide for all face mounted instnammu. .. Remove the instrument &eCas panel by removinJ the retaiDinI screws and liftint off the panel. b. Remove the face panel by removinl the KrftIS from around the perimeter of the panel. c.

With the face panel removed. the mountinJ screws for the iftdividua1 iastNmena will be exposed. d. Disconnect the plumbq aneIIor decuica1 connector from the back of the instrument. Where two or more lines COMect to an iDsaurnmt, ideacify each liDe to fKililace reinaalIation. Attach a dust cap or pluS to each finia,. c. Remove the screws that secure the instrument in the pUleI CUtout. f. Remove the instrument from the pando InstaUation of tbe instrummts is in rcYCnC order pm for ranoVll. Ahu the installation is completed and before replacing the inStrUmmt access paae1. check aU componena for security and clearance of the conuol column.

A cluster is loc:ated on the instrument pand &Ild contains sevcnJ individual inStrUments. Removal of the instrument face panel will depose the clear plutic cover on the cl\lSftl'. Rmsove this cover by removing the two center mounting screws. Aim the plumbiq and/or dectric:al connection bu been removed and idencified. the individual inmument may be removed from the cluster IIICDlbly. 11-9. G)'IO SerYice Proadurc. 11-10. G)'!'O IJuaIlation IDIpeftioD. The foUowiDa inrpectiolll should be made before removiftl a mspectcd JYfO inmumeDt from the airplane. Visual ExaminatioQ: a, Has the insaument beeQ modified? b. Has the insaument been damaged? c. Does the insaummt show any sips of abuse?

NOTE 00 not cage directional IYro and Set to different headinp. The entire gyro and fixture must be rotated 90 dqrec:s each time without touching 3 F20 INSTRUMENTS REVISED: 6/25/78