STRUCTURE, FUNCTION AND MAINTENANCE STANDARD HSS OIL COOLER BYPASS VALVE HSS OIL COOLER BYPASS VALVE 1. Plug 2. Poppet 3. Spring 4. Body Outline This valve is installed in the circuit between the HSS pump oil return circuit and the oil cooler. If any abnormal pressure is generated in the oil flowing to the oil cooler, this valve acts to return the oil directly to the hydraulic tank. Cracking pressure: 0.304 MPa {3.10 kg/cm 2 } A: From CLSS valve B: To hydraulic tank C: To oil cooler Unit: mm D85EX-15 10-67 No.
Check item Criteria Remedy 3 Spring Standard size Repair limit Replace Installed Free length length Installed load Free length Installed load 94.8 74.8 296N {30kg} 88 279N {28.5kg} 5 Clearance between oil cooler by- pass valve and valve body Tolera Standard size Shaft nce Standard clearance Clearance limit Hole – 0.050 50 – 0.089 + 0.20 + 0.10 0.150– 0.289 0.30