STRUCTURE, FUNCTION AND MAINTENANCE STANDARD COOLING FAN PUMP Operation 1. Operation of pump Cylinder block (7) rotates together with shaft (1) and shoe (5) slides on plane A . At this time, rocker cam (4) tilts around ball (11). As a result, angle between center line X of rocker cam (4) and the axis of cylinder block (7) changes. Angle is called the swash plate angle. If angle is made between center line X of rocker cam (7) and the axis of cylinder block (7), plane A works as a cam for shoe (5). Accordingly, piston (6) slides inside cylinder block (7) and a difference is made between vol- umes E and F in cylinder block (7). As a result, each piston (6) sucks and discharges oil by F - E .
In other words, if cylinder block (7) rotates and the volume of chamber E is decreased, the oil is discharged from chamber E . On the other hand, the volume of chamber F is increased and the oil is sucked in chamber F . (In the figure, chamber F is at the end of the suction stroke and chamber E is at the end of the discharge stroke.) If center line X of rocker cam (4) is equal to the axial of cylinder block (7) (the swash plate angle is 0), there is not a difference between volumes E and F in cylinder block (7) and oil is not sucked or discharged. (The swash plate angle is not set to 0 actually, however.) In short, swash plate angle is in proportion to the pump discharge. D85EX-15 10-121